Schneider MasterPact NW16H2 4 Pole 1600A Air Circuit Breaker
₨ 1,600,000
₨ 1,200,000
- Range: MasterPacT
- Product name: MasterPact NW
- Circuit breaker name: MasterPact NW16H2
- Product or component type: Circuit breaker
- Net weight: 65 kg
- Device application: Power distribution protection
- Poles description: 4P
- Neutral position: Right
- Control unit: Without control unit
- Selectivity category: Category B
- Control type: Push-button
- Mounting mode: Fixed
Additional information
| Ampere Rating | 1600A |
|---|---|
| No of Pole | 4 Pole |
Product Specifications
|
Range
|
masterpact
|
|
product name
|
masterpact nw
|
|
circuit breaker name
|
masterpact nw16h2
|
|
product or component type
|
circuit breaker
|
|
net weight
|
65 kg
|
|
device application
|
power distribution protection
|
|
poles description
|
4p
|
|
neutral position
|
right
|
|
control unit
|
without control unit
|
|
rated current [in]
|
1600 a at 40 °c
|
|
performance type
|
h2 100 ka 440 v ac
|
|
rated operational voltage [ue]
|
690 v ac 50/60 hz
|
|
suitability for isolation
|
yes conforming to en/iec 60947-2
|
|
selectivity category
|
category b
|
|
control type
|
push-button
|
|
mounting mode
|
fixed
|
|
rated ultimate short-circuit breaking capacity [icu]
|
100 ka at 220/415 v ac 50/60 hz / 100 ka at 440 v ac 50/60 hz / 85 ka at 525 v ac 50/60 hz / 85 ka at 690 v ac 50/60 hz
|
|
rated service breaking capacity [ics]
|
100 ka at 220/415 v ac 50/60 hz / 100 ka at 440 v ac 50/60 hz / 85 ka at 525 v ac 50/60 hz / 85 ka at 690 v ac 50/60 hz
|
|
rrated short-time withstand current [icw]
|
85 ka 1 s / 50 ka 3 s
|
|
rated short-circuit making capacity [icm]
|
220 ka 220/415 v ac at 50/60 hz / 187 ka 440 v ac at 50/60 hz / 187 ka 525 v ac at 50/60 hz / 187 ka 690 v ac at 50/60 hz
|
|
integrated instantaneous protection (din in ka peak)
|
171…209 ka
|
|
sensor rating
|
800 a / 1600 a
|
|
rated insulation voltage [ui]
|
1000 v ac 50/60 hz
|
|
rated impulse withstand voltage [uimp]
|
12 kv
|
|
power dissipation in w
|
170 w
|
|
maximum breaking time
|
25 ms
|
|
maximum closing response time
|
70 ms
|
|
mounting support
|
backplate / rails
|
|
upside connection
|
front / rear
|
|
downside connection
|
front / rear
|
|
connection pitch
|
115 mm
|
|
mechanical durability
|
12500 cycles without maintenance / 25000 cycles with maintenance
|
|
electrical durability
|
10000 cycles 440 v ac 50/60 hz without maintenance conforming to en/iec 60947-2 / 10000 cycles 690 v ac 50/60 hz without maintenance conforming to en/iec 60947-2 / ac-23a; 10000 cycles 440 v ac 50/60 hz without maintenance conforming to en/iec 60947-3 / ac-23a; 10000 cycles 690 v ac 50/60 hz without maintenance conforming to en/iec 60947-3 / ac-3; 6000 cycles 440/690 v ac 50/60 hz without maintenance conforming to en/iec 60947-3
|
|
ip degree of protection
|
ip30 conforming to iec 60529
|
|
pollution degree
|
4 conforming to iec 60664-1
|
|
ambient air temperature for operation
|
-25…70 °c
|
|
ambient air temperature for storage
|
-40…85 °c
|
|
operating altitude
|
0…2000 m without derating / 2000 m…5000 m with derating
|
Product Details
Schneider MasterPact NW16H2 is a high-performance 4-pole air circuit breaker designed for robust electrical circuit protection. With a rated current of 1600A, this breaker is equipped to handle heavy-duty applications, ensuring reliable and efficient protection against overloads and short circuits. Its advanced design incorporates cutting-edge technology to deliver superior performance and enhance electrical system safety. The NW16H2 is a versatile solution suitable for various industrial and commercial environments, offering a combination of high current-carrying capacity and precision in circuit interruption. Schneider’s MasterPact series is renowned for its durability and innovation in the field of electrical distribution, making the NW16H2 a reliable choice for demanding applications.