Schneider LC1–G1154 TeSys Giga, 4 pole (4NO), AC-1 <=440V 250A standard Coil
₨ 155,000
₨ 116,250
- Supports up to 440V AC-1 with a 250A current rating.
- Suitable for industrial control and power distribution.
- Ensures efficient and stable switching.
- Withstands harsh environments, vibrations, and stress.
- User-friendly mounting for quick setup.
- Reduces power loss and improves efficiency.
- Durable design minimizes maintenance costs.
- Meets IEC, UL, and CSA standards for secure operation.
Additional information
| Ampere Rating | 250A |
|---|---|
| No of Pole | 4 Pole |
Product Specifications
|
Range
|
tesys
|
|
range of product
|
tesys giga
|
|
product or component type
|
contactor
|
|
device short name
|
lc1g
|
|
contactor application
|
power switching
|
|
utilisation category
|
ac-3, ac-3e, ac-1, ac-5a, ac-5b, ac-6a, ac-6b, dc-1, dc-3, dc-5
|
|
poles description
|
4p
|
|
[ue] rated operational voltage
|
≤ 1000 v ac 50/60 hz, ≤ 460 v dc
|
|
[ie] rated operational current
|
115 a (≤ 440 v ac-3, <60 °c), 250 a (≤ 1000 v ac-1, <40 °c)
|
|
[uc] control circuit voltage
|
100…250 v ac 50/60 hz, 100…250 v dc
|
|
control circuit voltage limits
|
operational
|
|
[uimp] rated impulse withstand voltage
|
8 kv
|
|
overvoltage category
|
iii
|
|
[ith] conventional free air thermal current
|
250 a (at 40 °c)
|
|
rated breaking capacity
|
1040 a at 440 v
|
|
[icw] rated short-time withstand current
|
1.1 ka – 10 s, 0.64 ka – 30 s, 0.52 ka – 1 min, 0.4 ka – 3 min, 0.32 ka – 10 min
|
|
associated fuse rating
|
125 a am (≤ 440 v for motor), 125 a am (≤ 690 v for motor), 315 a gg (≤ 690 v)
|
|
average impedance
|
0.00018 ohm
|
|
[ui] rated insulation voltage
|
1000 v
|
|
power dissipation per pole
|
10 w (ac-1, ith 250 a), 3 w (ac-3, ith 115 a)
|
|
compatibility code
|
lc1g
|
|
pole contact composition
|
4 no
|
|
auxiliary contact composition
|
1 no + 1 nc
|
|
irms rated making capacity
|
1560 a at 440 v
|
|
coil technology
|
built-in bidirectional peak limiting
|
|
safety reliability level
|
b10d = 400,000 cycles (nominal load) conforming to en/iso 13849-1, b10d = 3,000,000 cycles (mechanical load) conforming to en/iso 13849-1
|
|
mechanical durability
|
8 mcycles
|
|
inrush power in va (50/60 hz, ac)
|
540 va
|
|
inrush power in w (dc)
|
380 w
|
|
hold-in power consumption in va (50/60 hz, ac)
|
12.4 va
|
|
hold-in power consumption in w (dc)
|
7.8 w
|
|
operating time
|
40…70 ms closing, 15…50 ms opening
|
|
maximum operating rate
|
600 cyc/h (ac-3, ac-3e), 300 cyc/h (ac-1)
|
|
power circuit
|
bar 2 – busbar cross section
|
|
power circuit
|
lugs-ring terminals 1 185 mm²
|
|
control circuit
|
push-in 1 (0.2…2.5 mm² solid stranded without cable end)
|
|
control circuit
|
push-in 1 (0.25…2.5 mm² flexible with cable end)
|
|
control circuit
|
push-in 2 (0.5…1.0 mm² with cable end)
|
|
control circuit
|
push-in 0.75…2.5 mm² (solid stranded without cable end)
|
|
control circuit
|
push-in 0.75…2.5 mm² (flexible with cable end)
|
|
connection pitch
|
35 mm
|
|
mounting support
|
plate
|
|
tightening torque
|
18 n.m height
|
|
width
|
143 mm
|
|
depth
|
193 mm
|
|
net weight
|
4.4 kg
|
Product Details
TeSys Giga high power contactor, 4 poles (4 NO) for category AC-1 applications up to 250A @440V. Equipped with 100-250 V AC/DC wide band low consumption electronic coil and embedded highly reliable 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 300 cycles per hour and environments up to 60°C. It’s built with high reliability delivering mechanical durability up to 8 million cycles. Contact Wear Diagnosis (CWD) is a standard function, which continuously monitors and provide feedback through healthy and alarm conditions by an LED indicator. It is possible to replace switching module (main contacts), control module enhancing contactor life with simple maintenance activities. Front accessible main power connections are with bolted connection and control connections by push-in terminals for easy and quick assembly. It provides IP2x protection from front face with optional terminal shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, with no derating up to 3000m altitude. Contactor can be installed in three quadrants of vertical plane, and OLR could be directly mounted below contactor. The dimensions are 193 mm x 143 mm x 193 mm (H x W x D), compact size enables panel space savings. Multi standards certified (CB, CCC, cULcs, CE, UKCA marking). Unique QR code provides quick access to complete product data.