Schneider EZC100F 3 Pole Molded Case Circuit Breaker, 10 kA
₨ 14,500
₨ 10,875
- Range of product: EasyPact
- Product or component type: Circuit breaker
- device short name: Easypact EZCI OOF
- circuit breaker name: Easypact EZCI OOF
- Device application: Distribution
- Poles description: 3P
- Protected poles description: 3t
- Network type: DC/AC
- Network frequency: 50/60 Hz
Additional information
| Ampere Rating | 15A, 20A, 30A, 40A, 50A, 60A, 80A, 100A |
|---|---|
| No of pole | 3 Pole |
Product Specifications
|
Range of product
|
easypact
|
|
product or component type
|
circuit breaker
|
|
device short name
|
easypact ezci oof
|
|
circuit breaker name
|
easypact ezci oof
|
|
device application
|
distribution
|
|
poles description
|
3p
|
|
protected poles description
|
3t
|
|
network type
|
dc/ac
|
|
network frequency
|
50/60 hz
|
|
[in] rated current
|
100 a at 40 oc
|
|
[ui] rated insulation voltage
|
690 v ac 50/60 hz conforming to iec 60947-2
|
|
[uimpj rated impulse withstand voltage
|
6 kv conforming to iec 60947-2
|
|
breaking capacity code
|
f
|
|
breaking capacity
|
10 ka icu at 380 v ac 50/60 hz conforming to iec 60947-2 / 10 ka icu at 400…415 v ac 50/60 hz conforming to iec 60947-2
|
|
suitability for isolation
|
yes conforming to iec 60947-2
|
|
utilization category
|
category a
|
|
trip unit name
|
tm-d
|
|
trip unit technology
|
thermal-magnetic
|
|
trip unit rating
|
100 a at 50 oc
|
|
protection type
|
short-circuit protection / overload protection
|
|
pollution degree
|
3 conforming to iec 60664-1 / 3 conforming to iec 947-1
|
|
control type
|
toggle
|
|
mounting mode
|
fixed
|
|
mounting support
|
backplate
|
|
upside connection
|
front
|
|
downside connection
|
front
|
|
mechanical durability
|
8500 cycles
|
|
standards
|
ewiec 60947-1 / jis c8201q-2 / gbi’t 14048.2 / ewiec 60947-2
|
|
ip degree of protection
|
ip20 conforming to iec 60529
|
|
1k degree of protection
|
ik07 conforming to iec 62262
|
|
ambient air temperature for operation
|
-25..-70 c
|
|
ambient air temperature for storage
|
-35…85 c
|
Product Details
EasyPact EZC100F is a 3 poles fixed circuit breaker designed for the protection of low-voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at a competitive price The breaking capacity (Icu) is 10kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 15A, 20A, 30A, 40A, 50A, 60A, 80A, 100A. The trip unit provides fixed overload and instantaneous protection. This 3-pole version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100F is compliant with international standards (IEC 60947, UL 508) and marine certifications.
User Manual
schneider-ezc100f-3p-circuit-breaker-15a
schneider-ezc100f-3p-circuit-breaker-20a
schneider-ezc100f-3p-circuit-breaker-30a
schneider-ezc100f-3p-circuit-breaker-40a
schneider-ezc100f-3p-circuit-breaker-50a
schneider-ezc100f-3p-circuit-breaker-60a









Reviews