Schneider EZC400N 3 Pole Molded Case Circuit Breaker, 36 kA

 100,000
 75,000

  • Range Of product: EasyPact
  • Product or component type: Circuit breaker
  • Device short name: Easypact EZC400N
  • circuit breaker name: Easypact EZC400N
  • Device application: Distribution
  • Poles description: 3P
  • Protected poles description: 31
  • Network type: AC/DC
  • Network frequency: 50/60 Hz

Additional information

Ampere Rating

320A, 400A

No. of Pole

3 Pole

Product Specifications

Range of product
easypact
product or component type
circuit breaker
device short name
easypact ezc400n
circuit breaker name
easypact ezc400n
device application
distribution
poles description
3p
protected poles description
31
network type
ac/dc
network frequency
50/60 hz
[in] rated current
400 a at 40 oc
[ui] rated insulation voltage
690 v ac 50/60 hz conforming to iec 60947-2
[uimpj rated impulse withstand voltage
6 kv conforming to iec 60947-2
[uel rated operational voltage
250 v dc conforming to iec 60947-2 / 440 v ac 50/60 hz conforming to iec 60947-2
breaking capacity code
n
breaking capacity
36 ka
suitability for isolation
yes conforming to iec 60947-2
utilisation category
category a
trip unit name
tm-d
trip unit technology
thermal-magnetic
trip unit rating
320 a at 50 oc
protection type
overload protection / short-circuit protection
pollution degree
3 conforming to iec 60947
mechanical durability
10000 cycles
standards
jis c8201-2-2 / en/iec 60947-2 / gbi’t 14048.2 / en/iec 60947-1
ip degree of protection
ip20 conforming to iec 60529
1k degree of protection
ik07 conforming to en 50102
ambient air temperature for operation
-25…70 c
ambient air temperature for storage
-35…85 c

Product Details

This is a 320A, 400A circuit breaker for EasyPact EZC400N. This product can work below rated operational voltage(Ue) 440VAC at 50/60Hz. The ultimate breaking capacity(Icu) is 50kA at 440V, in terms of complete range Ics=100%Icu(Ics= 50%Icu at 440V. This version of the product is designed 3-pole frame with detection on 3 poles, equipped TMD trip unit for thermal-magnetic protection. It complies with standard IEC60947, CE certification, and some independent labs (KEMA, ASEFA, TUV) or third-party Tilva. This device is certified for operation in a pollution degree III environment as defined by IEC60947 and passes the test of extreme atmospheric conditions. The device can be mounted vertically or horizontally in a metal enclosure, and against safety risk by padlocking. The degree of protection is IP40 for the direct rotary handle and IP54 for the extended rotary handle. This series has slots used for indication or voltage release auxiliaries positioning, depending on where it is inserted in the device behind the front cover of the circuit breaker. The fixed dimension is 140mm(width),255mm(height),110mm(Depth).

User Manual

schneider-ezc400h-3p-mccb-breakers-320a_d6916fe8-a057-4ebd-85ff-f9d7b1510cf9.pdf