Schneider LC1–G2654 TeSys Giga, 4 pole (4NO), AC-1 <=440V 385A AC/DC Coil
₨ 490,000
₨ 367,500
- Series: TeSys Giga
- Poles: 4P (4NO)
- Application: Power switching for industrial use
- Rated Operational Voltage: ≤ 1000V AC / ≤ 460V DC
- Rated Current: 185A (AC-3), 385A (AC-1)
- Control Voltage: 100-250V AC/DC
- Impulse Withstand Voltage: 8kV
- Durability: 8 million mechanical cycles
- Certifications: CE, CCC, cULus, EAC, UKCA, CB Scheme
Additional information
| Ampere Rating | 385A |
|---|---|
| No of Pole | 4 Pole |
Product Specifications
|
Series
|
tesys giga
|
|
product type
|
contactor
|
|
device short name
|
lc1g
|
|
poles
|
4p (4no)
|
|
rated operational voltage
|
≤1000v ac / ≤460v dc
|
|
rated current
|
265a (ac-3), 385a (ac-1)
|
|
control voltage
|
100-250v ac/dc
|
|
impulse withstand voltage
|
8kv
|
|
breaking capacity
|
2380a at 440v
|
|
short-time withstand current
|
up to 2.2ka for 10s
|
|
insulation voltage
|
1000v
|
|
coil technology
|
built-in bidirectional peak limiting
|
|
mechanical durability
|
up to 8 million cycles
|
|
operating time
|
closing (40-70ms), opening (15-50ms)
|
|
mounting
|
plate-mounted
|
|
certifications
|
cb scheme, ccc, culus, eac, ce, ukca, eu-ro-mr (dnv-gl)
|
|
dimensions
|
225mm (h) × 185mm (w) × 226mm (d)
|
|
net weight
|
8.3kg
|
Product Details
TeSys Giga high power contactor, 4 poles (4 NO) for category AC-1 applications up to 385A @440V. It provides a 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 185mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.






















Reviews
There are no reviews yet.