Schneider LC1–G500 TeSys G Contactor, 3P High Power Contactor

 625,000
 468,750

  • Handles high-power loads for industrial use
  • 3P design ensures efficient motor control and switching
  • Suitable for power distribution, automation, and machinery
  • Optimized coil voltage for stable and energy-efficient operation
  • Durable construction ensures long service life
  • Compact design for easy panel integration
  • Meets IEC safety standards for reliable performance
  • Screw clamp terminals for quick and secure wiring

Additional information

Ampere Rating

500A

No of Pole

3 Pole

Product Specifications

Range
tesys
range of product
tesys giga
product or component type
contactor
device short name
lc1g
contactor application
Power switching
motor control utilisation category
ac-1 ac-3 ac-3e ac-4 ac-5a ac-5b ac-6a ac-6b ac-8b ac-8a dc-1 dc-3 dc-5
poles description
3p
[ue] rated operational voltage
<= 1000 v ac 50/60 hz <= 460 v dc
[ie] rated operational current
700 a (at <40 °c) at <= 1000 v ac-1 500 a (at <60 °c) at <= 440 v ac-3
[uc] control circuit voltage
200…500 v ac 50/60 hz 200…500 v dc
control circuit voltage limits
operational
[uimp] rated impulse withstand voltage
8 kv
overvoltage category
iii
rated breaking capacity
4600 a at 440 v
[icw] rated short-time withstand current
4.0 ka – 10 s 2.8 ka – 30 s 2.2 ka – 1 min 1.5 ka – 3 min 1.2 ka – 10 min
associated fuse rating
500 a am at <= 440 v for motor 400 a am at <= 690 v for motor 800 a gg at <= 690 v
average impedance
0.00008 ohm
[ui] rated insulation voltage
1000 v
power dissipation per pole
40 w ac-1 – ith 700 a 20 w ac-3 – ith 500 a
compatibility code
lc1g
pole contact composition
3 no
auxiliary contact composition
1 no + 1 nc
motor power kw
147 kw at 230 v ac 50/60 hz (ac-3e) 250 kw at 400 v ac 50/60 hz (ac-3e) 250 kw at 415 v ac 50/60 hz (ac-3e) 280 kw at 440 v ac 50/60 hz (ac-3e) 315 kw at 500 v ac 50/60 hz (ac-3e) 355 kw at 690 v ac 50/60 hz (ac-3e) 335 kw at 1000 v ac 50/60 hz (ac-3e) 160 kw at 230 v ac 50/60 hz (ac-3) 250 kw at 400 v ac 50/60 hz (ac-3) 250 kw at 415 v ac 50/60 hz (ac-3) 315 kw at 440 v ac 50/60 hz (ac-3) 355 kw at 500 v ac 50/60 hz (ac-3) 355 kw at 690 v ac 50/60 hz (ac-3) 335 kw at 1000 v ac 50/60 hz (ac-3) 150 kw at 230 v ac 50/60 hz (ac-4) 250 kw at 400 v ac 50/60 hz (ac-4) 250 kw at 415 v ac 50/60 hz (ac-4) 295 kw at 440 v ac 50/60 hz (ac-4) 295 kw at 500 v ac 50/60 hz (ac-4) 355 kw at 690 v ac 50/60 hz (ac-4) 280 kw at 1000 v ac 50/60 hz (ac-4)
motor power hp
150 hp at 200/208 v 60 hz 200 hp at 230/240 v 60 hz 400 hp at 460/480 v 60 hz 450 hp at 575/600 v 60 hz
coil technology
Built-in bidirectional peak limiting
safety reliability level
b10d = 400000 cycles contactor with nominal load conforming to en/iso 13849-1 b10d = 3000000 cycles contactor with mechanical load conforming to en/iso 13849-1
mechanical durability
8 mcycles
inrush power in va (50/60 hz, ac)
535 va
inrush power in w (dc)
300 w
hold-in power consumption in va (50/60 hz, ac)
15.4 va
hold-in power consumption in w (dc)
8.6 w
operating time
40…70 ms closing 15…50 ms opening
tightening torque
35 n.m
height
290 mm
width
140 mm
depth
226 mm
net weight
7.8 kg

Product Details

The Schneider LC1–G500 TeSys G Contactor is a high-performance solution designed for industrial applications requiring reliable power switching and motor control. Built to handle heavy electrical loads, this 3P contactor ensures efficient operation in power distribution, automation, and machinery. With a durable design and optimized coil voltage, it provides long-lasting performance while maintaining energy efficiency. Its compact structure allows easy integration into control panels, and compliance with IEC safety standards ensures secure and stable operation. The screw clamp terminals simplify installation, making it a convenient choice for professionals.